Now showing 1 - 10 of 21
  • Placeholder Image
    Publication
    Prediction of the tensile capacity of cold formed angles experiencing shear lag
    (01-11-2011)
    Prabha, P.
    ;
    ;
    Saravanan, M.
    ;
    Marimuthu, V.
    The present study deals with the shear lag phenomenon in cold formed angles under tension, which are connected on one leg. A new expression for shear lag factor which represents the net section reduction coefficient has been suggested in the present paper. The proposed expression based on the regression analysis of 108 experimental results reported in the literature is validated by experiments involving net section failure in angles under tension. Totally 18 experiments were carried out on single angles fastened with bolts to the gusset plates under tension loaded upto net section rupture mode of failure. The experimental test parameters considered are number of bolts, pitch and shear lag distances and ratio of connected leg length to unconnected leg length. The tensile capacities are evaluated by various specifications such as AS/NZS:4600:2005, NAS:2001, AISC:2005, BS:5950-Part5:1998, IS:800-2007 and the proposed equation. A comparative study of tensile capacities predicted based on various codes and the experiment results is presented in this paper. For the tested range of specimens, both NAS:2001 and AISC:2005 standards over-predicted the capacities for all the specimens. The IS:800-2007 and AS/NZS 4600:2005 predictions are good for the specimens with three bolted connections and unconservative in the case of specimen with two bolts. Both BS:5950-Part-5:1998 and the proposed equation for IS:801 predict good estimate of the tensile capacity of cold formed angle members. The proposed equation for cold formed steel tension members, which is in the same format of IS:800 (2007) (Indian code for Hot rolled steel design), has been demonstrated to be good. © 2011 Elsevier Ltd. All rights reserved.
  • Placeholder Image
    Publication
    Investigation on the effect of shear connector in composite space structures
    (01-01-2013)
    Lakshmikandhan, K. N.
    ;
    Sivakumar, P.
    ;
    Ravichandran, R.
    ;
    ;
    Senthil, R.
    Space structures are common in covering large area with few or no intermittent supports. The catastrophic failures of space structures are frequently reported and it urges to develop suitable techniques to prevent such failures. The composite space structures are found to be an efficient solution, in which the forces in the critical compression members are redistributed and safe guarded with concrete slabs. In this study, numerical studies were conducted using a standard finite element analysis package. Effect of shear connectors with varying heights on the behaviour of the space structure is studied. Results are compared with the steel space structure and composite space structure with full shear interaction. The maximum deflection observed in the steel space structure for the service load is less than span/300 and the maximum deflection observed in the steel concrete composite space structure for the service load is less than span/360, which ensures the serviceability conditions. The results show about 20 to 30 percent of reduction in deflection with about 250 percent increase in stiffness due to the composite action for the service load. The results substantiate that the length of shear connector should be equal to the concrete depth for more efficient composite interaction. The composite action is more effective and efficient in composite space structure for larger spans compared to shorter spans.
  • Placeholder Image
    Publication
    Twlight-iitm—a computational utility for elastic buckling stress predictions of cold-formed steel elements
    (01-01-2019)
    Ajeesh, S. S.
    ;
    A new design method, Direct Strength Method (DSM), has been introduced by researchers in recent years for calculating the ultimate design strength of cold-formed steel sections. DSM is basically a stress-based approach, wherein the strength of the section is reduced to take care of buckling effects. The ultimate strengths corresponding to three buckling modes, local, distortional, and global modes are distinguished in DSM, in which the elastic buckling stresses are determined using analytical expressions or by using numerical methods like finite element, finite strip, or spline finite strip method. A finite strip computational procedure for evaluating the critical elastic buckling stresses has been proposed in the present study. Also, decomposition of buckling modes into pure modes can be performed using the formulation. This formulation has been validated for a range of cross-sectional dimensions under uniaxial compression and flexure and can be used as a design utility for IS 801 based on DSM.
  • Placeholder Image
    Publication
    A Computational Method for the Inelastic Postbuckling of Steel Space Structures with Bolt Slip
    (01-05-2017)
    Ramalingam, Raghavan
    ;
    The nonlinear behavior of space structures has been researched by various authors using the total and updated Lagrangian formulations. In this paper, a corotated-updated Lagrangian (CR-UL) formulation is used for studying the postbuckling behavior of steel reticulated systems. This formulation is used since space truss elements contain large components of rigid body displacements. The global tangent stiffness is derived from the corotation (CR) principle and the local (natural) tangent stiffness is derived using the updated Lagrangian (UL) finite element formulation. A state determination procedure is used for including the inelastic behavior with mixed hardening. Here members are assumed to reach the material strength limit state, which is reasonable in large span space structures based on serviceability governed design, with no consideration made for member buckling. The effect of bolt slip in the member joints is included by using a sudden slip model under the service loads. The global nodal displacements and coordinates are updated based on the analytical model of the bolt slip displacement using a simple affine transformation. The effect of bolt slip on the global displacements and member forces has been studied and compared with the results of previous authors.
  • Placeholder Image
    Publication
    Experimental investigations on behaviour of cold formed steel stub uprights
    (01-10-2017)
    Mohan, Vimal
    ;
    ;
    Kallapa, M. S.
    Uprights act as a column member in the rack system. In pallet racking systems, all upright sections are perforated to accept the hooks of the beam end connector and are the heart of the structural system. The perforations not only play an important role in the rack industry (for holding component in place), but are prone to more problems compared to any other form of structural member without perforation. The present study focuses on the behavior of perforated uprights under axial concentric loading. For better understanding, experiments were conducted on four specimens of steel rack uprights, by varying the thickness of sections as 1.6 and 1.8 mm with limitation on the slenderness ratio 10 and 18. Experimental investigations on the cold formed upright sections were studied for different type of configuration and their results are presented. Stress distribution across the specimen is also presented.
  • Placeholder Image
    Publication
    Stability evaluation of cold formed steel pallet racks under seismic condition-A numerical and shake table study
    In this paper, studies on global behaviour of cold formed steel pallet rack systems using a second-order frame analysis formulation are reported. Calibration studies on the developed second-order beam formulation have been carried out. The different global analysis procedures stipulated in the popular code of practice for the design of cold formed steel storage racks (EN 15512 and RMI (2012)) are briefly reviewed. Using the formulation, studies are carried out on tall racks, especially focusing on semi-rigidity of connections and stability. Later, a shake table test is conducted on a two-level pallet rack to investigate the dynamic behaviour of cold formed steel racks subjected to base excitation. A typical earthquake input of El Centro (1940) North-South component is applied, and the behaviour of the cold formed steel racks is studied. The connection flexibility of the upright - connector tab has been taken from an earlier publication by the author. All joints in the numerical model and experimental work are treated as semi rigid. The paper then describes the effect of connection rigidity on the dynamic performance of the racks. Although the racks could not be subjected to its maximum design load per level, the dynamic characterization that is observed during the test is reported in this paper. It is identified that, a combined dynamic analysis calibrated with numerical solutions is the correct way to assess the seismic performance of cold formed storage racks.
  • Placeholder Image
    Publication
    Investigations on the wind uplift behaviour of standing seam cold formed steel roofing sheets
    (01-02-2018)
    Koshy, Mini
    ;
    There is a steady rise in the usage of cold formed sheets made as standing seam panels in the roofs of pre-engineered buildings. Nevertheless, there are also reports of failure of these roof panels while in service. The behaviour of these panels cannot be captured analytically. A literature study is carried out on the testing and design methods of the cold formed steel (CFS) metal roof system. It is seen from literature survey that none of the international codes of practice specifies the procedure for the calculation of structural capacity of a standing seam roof system unless supported by experimental evidence. In view of that, the structural performance of a standing seam CFS metal roof system under wind uplift is tested in a vacuum chamber as per ASTM E1592. The objective of the presented work is the study of the behaviour and failure modes of the rigid purlin-sheeting system with standing seam CFS panel under uplift. The paper presents the details of an experimental investigation to achieve this objective. This study and the experimental infrastructure is first of its kind in India. The paper also presents various limit states of sheeting - purlin interaction failure based on experimental evidences. It is concluded that in order to treat the sheet-purlin dual load resisting behaviour, the disengagement of the sheet with purlin through the halter must be avoided. One of the main conclusions of the work is the concept of adjustable halter length in regions of high pressure in the roofs.
  • Placeholder Image
    Publication
    Identification of buckling modes in generalized spline finite strip analysis of cold-formed steel members
    (01-10-2017)
    Ajeesh, S. S.
    ;
    In this paper, a mode identification technique in the context of spline finite strip method (SFSM) is presented to compute the contribution of primary (global, distortional and local) and secondary (shear/transverse extension) buckling modes. The base vectors corresponding to individual buckling modes are developed based on the principles of generalized beam theory. The buckling mode shape in SFSM is approximated as a linear combination of these orthonormal base vectors to evaluate the participation of individual buckling mode. The proposed mode identification technique is able to successfully quantify the participation of different buckling modes and the mode participation is comparable with mode identification using finite strip method (FSM) and generalized beam theory (GBT). Illustrative examples are presented to calculate the participation of individual modes in cold-formed steel sections under different loading and boundary conditions. Also the specific application of mode identification in SFSM is demonstrated.
  • Placeholder Image
    Publication
    Computational framework for mimicking prototype failure testing of transmission line towers
    (15-09-2016)
    Ramalingam, Raghavan
    ;
    Traditional analysis of transmission line tower structures gives good estimate of ultimate strength but deflection estimates are much less than actual deflections measured from tests. This is caused by additional deflections due to joint properties like bolt slip in splices and splice plate deformations. These two displacement contributing factors are difficult to include in analysis. Prototype tower testing in test beds, which provides design strength evaluation and actual deflections is expensive. This paper presents a simple analytical procedure which captures not only the ultimate load and associated deflections but also the additional deflections because of bolt slip in leg splices. The formulation incorporates a corotational updated Lagrangian procedure in finite element analysis framework. The additional deflections are integrated into a nonlinear analysis formulation used for reticulated structures which also considers member buckling and yielding. To demonstrate the applicability of the formulation, towers which were experimentally tested in test beds are studied and the results are compared with strength and deflection measurements. The formulation has been demonstrated to be a reasonable alternative to expensive proto type testing.
  • Placeholder Image
    Publication
    Automatic scheme for inelastic column buckling
    (01-01-2016)
    Ramalingam, Raghavan
    ;
    The inelastic buckling of columns is difficult to model analytically. Methods like FEM or approximate closed form expressions are presently available but they are unsatisfactory for reasons mentioned in this paper. In this study, the inelastic buckling of columns is modelled to reflect the true curves upto the ultimate load prior to and except the rapid unloading. The method aims to be a helpful supplement to assist in predicting failure loads and modes during experimental testing of columns in intermediate slenderness ranges. The method combines the iterative Newmark's approach for eccentrically loaded columns with the arc-length displacement control scheme to direct the load increments. The results obtained are verified with known behaviour of column buckling with respect to slenderness, mode of failures, imperfections etc. The method simulated the load-deflection and failure mode of columns of various slenderness with reasonable accuracy.