    Characterization and ultrasound-pulse mediated destruction of ultrasound contrast microbubbles
    (01-12-2006)
    Sarkar, Kausik
    ;
    Jain, Pankaj
    ;
    Intravenously injected encapsulated microbubbles improve the contrast of an ultrasound image. Their destruction is used in measuring blood flow, stimulating arteriogenesis, and drug delivery. We measure attenuation and scattering of ultrasound through solution of commercial contrast agents such as Sonazoid and Definity. We have developed a number of different interfacial rheology models for the encapsulation of such microbubbles. By matching with experimentally measured attenuation, we obtain the characteristic rheological parameters. We compare model predictions with measured subharmonic responses. We also investigate microbubble destruction under acoustic excitation by measuring time-varying attenuation data. © 2006 American Institute of Physics.
  • Placeholder Image
    Publication
    Modeling and characterization of encapsulated microbubbles for ultrasound imaging and drug delivery
    (11-09-2008)
    Sarkar, Kausik
    ;
    Jain, Pankaj
    ;
    Intravenously injected encapsulated microbubbles improve the contrast of an ultrasound image. Their destruction is used in measuring blood flow, stimulating arteriogenesis, and drug delivery. We measure attenuation and scattering of ultrasound through solution of commercial contrast agents such as Optison (GE Health Care, Princeton, NJ) and Definity (Bristol Meyer-Squibb Imaging, North Ballerina, MA). We have developed an interfacial rheology model for the encapsulation of such microbubbles. By matching with experimental data, we obtain the characteristic rheological parameters. We compare model predictions with other experiments. We also investigate microbubble destruction under acoustic excitation by measuring time-varying attenuation data. Three regions of acoustic pressure amplitudes are found: at low pressure, there is no destruction; at slightly higher pressure bubbles are destroyed, and the rate of destruction depends on a combination of PRF and amplitude. At a still higher pressure amplitude, the attenuation decreases catastrophically. The last two regimes correspond respectively to 1) slow destruction of bubbles due to increased gas diffusion and 2) complete bubble destruction leading to release of free bubbles. An analytical model for the bubble growth and dissolution will be presented. The effects of membrane permeability and elasticity on the stability of microbubbles are investigated. (Supported by DOD, NSF and NIH). © 2008 American Institute of Physics.