    Publication
    Potentiometric biosensors based on silicon and porous silicon
    (02-11-2004)
    Basu, Indranil
    ;
    Subramanian, R. Venkata
    ;
    Mathew, Arun
    ;
    ;
    We report fabrication of potentiometric biosensors with silicon for the estimation of triglycerides and urea based on enzymatic reactions. The sensor is an Electrolyte-Insulator-Semiconductor capacitor (EISCAP) that shows a shift in the measured CV with changes in the pH of the electrolyte. Enzyme mediated biological reactions involve changes in the pH of the electrolyte and an EISCAP can be effectively used for detection of biological compounds. Optimization of the conditions for the enzymatic reaction and calibration of the sensor are included. Effect of replacing silicon with porous silicon is discussed.
  • Placeholder Image
    Publication
    Estimation of triglycerides by a porous silicon based potentiometric biosensor
    (01-04-2003)
    Kumar Reddy, R. Ravi
    ;
    Basu, Indranil
    ;
    ;
    A novel, enzymatic, porous silicon (PS) based potentiometric method for estimating triglycerides is reported. Lipase, an enzyme, which hydrolyses triglycerides was immobilised on PS which was prepared from p-type (1 0 0) crystalline silicon and was thermally oxidized. On hydrolysis the triglycerides result in the formation of fatty acids which causes a change in the pH of the solution. Enzyme solution-oxidized PS-crystalline silicon structure was used to detect changes in pH during the hydrolysis of tributyrin as a shift in the capacitance-voltage (C-V) characteristics. Optimisation of the conditions for the enzymatic reaction and calibration of the sensor are included. © 2002 Elsevier Science B.V. All rights reserved.
  • Placeholder Image
    Publication
    Porous silicon based potentiometric triglyceride biosensor
    (21-06-2001)
    Reddy, R. Ravi Kumar
    ;
    ;
    A novel method for estimating triglycerides is reported. Porous silicon, prepared from p-type (100) crystalline silicon was thermally oxidized and used to immobilise lipase, an enzyme, which hydrolyses triglycerides resulting in the formation of fatty acids. This causes a change in the pH of the solution. Enzyme solution-oxidized porous silicon-crystalline silicon structure was used to detect changes in pH during the hydrolysis of tributyrin as a shift in the capacitance-voltage (C-V) characteristics. Detailed calibration of the sensor is included. © 2001 Elsevier Science B.V.
  • Placeholder Image
    Publication
    Comparison of a potentiometric and a micromechanical triglyceride biosensor
    (01-01-2009)
    Fernandez, Renny Edwin
    ;
    Hareesh, Vemulachedu
    ;
    ;
    Sensitive biosensors for detection of triglyceride concentration are important. In this paper we report on two types of silicon based triglyceride sensors: an electrolyte-insulator-semiconductor capacitor (EISCAP) which is a potentiometric device and a polysilicon microcantilever. The detection principle for both sensors is based on the enzymatic hydrolysis of triglyceride though the sensing mechanisms are different: electronic for the EISCAP and mechanical for the microcantilever. The characteristics and performances of the two sensors are critically compared. The EISCAP sensor necessitates the presence of a buffer for stable measurements which limits the sensitivity of the sensor at low concentrations of the bioanalyte to 1 mM. The cantilever sensor works without a buffer which improves the lower level of sensitivity to 10 μm. Both sensors are found to give reproducible and reliable results. © 2008 Elsevier B.V. All rights reserved.
  • Placeholder Image
    Publication
    Studies on cantilever based triglyceride biosensor
    (01-12-2007)
    Fernandez, Renny Edwin
    ;
    Soma Sekhar, B. V.
    ;
    ;
    We report detection of micromolar levels of triglycerides using surface micromachined polysilicon cantilever beams. Enzymatic hydrolysis of triglycerides produces glycerol which alters the viscosity and density of the solution. This affects the dynamic properties of cantilever beams immersed in the solution. The change in the resonance frequency of the cantilever beams in the solution is measured using Doppler Vibrometry and the concentration of triglyceride is determined by comparing with a predetermined calibration plot. © 2007 IEEE.
  • Placeholder Image
    Publication
    Solid state potentiometric sensor for the estimation of tributyrin and urea
    (27-05-2005)
    Basu, Indranil
    ;
    Subramanian, Raman Venkata
    ;
    Mathew, Arun
    ;
    Kayastha, Arvind M.
    ;
    ;
    We report fabrication of a potentiometric biosensor on silicon for the estimation of tributyrin and urea based on enzymatic reactions. The sensor is an electrolyte-insulator-semiconductor capacitor (EISCAP) that shows a shift in the measured C-V with changes in the pH of the electrolyte. This pH shift can be induced by the enzyme-mediated hydrolysis of tributyrin and urea which results in acidic and basic solutions, respectively and an EISCAP can be effectively used for the detection of these bioanalytes. A silicon nitride based EISCAP was used for the first time to detect triglycerides and urea. The sensor was able to detect millimolar concentrations of the bioanalytes (tributyrin/urea). The most important features of the tributyrin and urea sensor are high sensitivity, long life-time, easily built at a low cost, micro-construction and short response time. Optimization of the conditions for the enzymatic reaction and calibration of the sensor are included. © 2004 Elsevier B.V. All rights reserved.