Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
Repository logo
  • Communities & Collections
  • Research Outputs
  • Fundings & Projects
  • People
  • Statistics
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Indian Institute of Technology Madras
  3. Publication2
  4. Phantom evaluation of a time warping based automated arterial wall recognition and tracking method
 
  • Details
Options

Phantom evaluation of a time warping based automated arterial wall recognition and tracking method

Date Issued
23-06-2021
Author(s)
Raj Kiran, V.
Nabeel, P. M.
Mohanasankar S 
Indian Institute of Technology, Madras
Jayaraj Joseph 
Indian Institute of Technology, Madras
DOI
10.1109/MeMeA52024.2021.9478692
Abstract
Ultrasound-based arterial wall recognition and tracking methods in the literature apply to two-dimensional ultrasound data, either in the form of B-mode images or M-lines radio-frequency (RF) data. We propose a robust dynamic time warping method that is applicable to just one-dimensional single scan-line RF signals. It uniquely analyses the time-varying effects of tissue dynamics on the amplitude and phase features of the RF signals. Its performance was investigated via systemic in-vitro experiments on a pulsatile flow phantom. The recording was performed by an ultrasound imaging system where the B-mode video clips and the raw RF data were saved simultaneously for direct comparison of the proposed method's versus B-mode reference measurements. The noise of different levels was added to the RF signals to evaluate the method's robustness. The method detected the arterial walls in 95% -100% of the frames (with SNRs ≥ 10 dB), and for ~100% of those detections, the method accurately localized the walls in the frames. Even when SNR levels were poor (0 dB < SNR < 5 dB) the detection and correct rates were greater than 80% and 90%. The performance figures were consistent for different pulsation rates (0.4 to 3 Hz) emulated. Further, the tracking errors were < 5% for frames with SNR ≥ 5 dB, which improved (errors < 3%) with an increase in SNR. The distension measurements resulting from tracking were repeatable over continuous pulsation cycles (CoV < 0.5%) and were accurate compared to B-mode measurement, with RMSE = 22 μm. The measured versus reference distensions strongly correlated (r = 0.99, p < 0.05) to each other and yielding insignificant (p = 0.17) difference of -6 μm. The method has the potential to facilitate an automated framework for A-mode-based structural and functional analysis of the blood vessels. Therefore, it allows the realization of advanced and cost-effective real-time A-mode systems.
Subjects
  • A-mode

  • Distension

  • Dynamic time warping

  • Echo-tracking

  • Radio-frequency

  • Wall-recognition

  • Wall-tracking