Abstract
To address the intermittency in solar energy system due to unforeseen weather conditions and to improve dispachability, the requirement of Thermal Energy Storage (TES) system is becoming increasingly inevitable. A single tank packed bed thermocline TES system has potential to provide an effective solution. A comprehensive one-dimensional non-thermal equilibrium model is considered and is solved using method of characteristics to investigate energy storage in a single tank packed bed thermocline storage system. Thermal characteristics including temperature profiles and discharge effectiveness with different commercially available Heat Transfer Fluids (HTFs) are explored and analyzed. A tank size of 12.5 m in height and 8 m in diameter is considered with a capacity of 40 MW htfor the present study. The effect of porosity on discharge effectiveness of the storage tank with different HTFs is investigated with porosity, ε varied from 0.1 to 0.7. It is found that the discharge effectiveness consistently drops when ε value increases from 0.1 to 0.7 for all the HTFs. Two-dimensional numerical simulation is also carried out to explore the transient temperature distribution inside the tank for different HTFs with a porosity of 0.2. It is observed that as the operation time of the tank increases, filler material eventually loses heat to adjacent fluid and attains equilibrium. The thermocline moves at a faster rate in Solar Salt than the HITEC due to its higher viscosity.
Volume
144