Publication: Understanding the partial discharge activity initiated by a conducting particle in GIS under DC voltages using UHF technique
Date
22-07-2009
Authors
Ramanujam Sarathi
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The major cause of failure of DC-GIS is due to presence of foreign particles causing partial discharges in the insulation structure. It is realized that the levitation voltage of a particle in GIS is independent of polarity of applied DC voltage and operating pressure. It is observed that particle movement in GIS radiates electromagnetic waves and the bandwidth of the signal lies up to 2 GHz. Increase in applied voltage/pressure has not altered the frequency content in the UHF signal measured. It is observed that absolute charge injected due to partial discharge formed due to particle movement increases with increase in voltage/ ambient pressure. It is also realized that partial discharge magnitude and the UHF signal amplitude have good correlation and show a proportionate increase. © 2009 FEI STU.
Description
Keywords
Discharges, GIS, HVDC, Partial discharges, SF 6, UHF