Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
Repository logo
  • Communities & Collections
  • Research Outputs
  • Fundings & Projects
  • People
  • Statistics
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Indian Institute of Technology Madras
  3. Publication2
  4. An Accelerometric Sensor System with Integrated Hydrostatic Pressure Correction to Assess Carotid Arterial Stiffness
 
  • Details
Options

An Accelerometric Sensor System with Integrated Hydrostatic Pressure Correction to Assess Carotid Arterial Stiffness

Date Issued
01-05-2021
Author(s)
Arathy, R.
Nabeel, P. M.
Abhidev, V. V.
Mohanasankar S 
Indian Institute of Technology, Madras
Jayaraj Joseph 
Indian Institute of Technology, Madras
DOI
10.1109/JSEN.2021.3059292
Abstract
Non-invasive evaluation of vascular stiffness has established utility in cardiovascular risk and stroke prediction. This work presents an accelerometric sensor-based system with an integrated hydrostatic pressure correction unit for arterial luminal diameter measurement and local vascular stiffness assessment. A custom-designed accelerometric patch for continuous monitoring of percutaneous acceleration plethysmogram (APG) from the common carotid artery, which could estimate the arterial wall displacement, was developed. A calibration model was established to estimate the true carotid luminal diameter waveform from the accelerometer-based arterial wall displacement signals. The system's accuracy for carotid stiffness measurement was validated by multiple in-vivo human subject studies and compared against a clinical-grade B-mode ultrasound imaging system. Accelerometric-derived carotid diameter waveform morphologically replicated the anachrotic, and dicrotic limb of the true carotid diameter recorded using reference devices. The group-average baseline value of measured carotid end-diastolic diameter and distension was 5.81 ± 0.53 mm and 0.51 ± 0.15 mm with a maximum observed beat-by-beat variation of 6.5% and 9%, respectively. Accelerometer-based vascular stiffness measures showed a significant correlation (R2 > 0.88, P < 0.0001), and clinically acceptable agreement with a reference standard imaging system. APG derived carotid stiffness indices demonstrated the capability to detect expected age-associated changes in stiffness. The study revealed that the accelerometric sensor system offers a reliable, cost-effective method for long-term non-invasive monitoring of location-specific vascular stiffness measures with potential applications in ambulatory healthcare monitors.
Volume
21
Subjects
  • Acceleration plethysm...

  • accelerometer sensor

  • cardiovascular diseas...

  • carotid luminal diame...

  • carotid wall displace...

  • common carotid artery...

  • vascular stiffness me...

Indian Institute of Technology Madras Knowledge Repository developed and maintained by the Library

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback