Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
Repository logo
  • Communities & Collections
  • Research Outputs
  • Fundings & Projects
  • People
  • Statistics
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Indian Institute of Technology Madras
  3. Publication3
  4. Design of a flexure-based compliant grasper for the master arm of a surgical robot
 
  • Details
Options

Design of a flexure-based compliant grasper for the master arm of a surgical robot

Date Issued
01-01-2021
Author(s)
Chandrasekaran, Karthik
Somayaji, Adarsh
Thondiyath, Asokan
DOI
10.1115/DMD2021-1037
Abstract
A master arm of a tele-operated surgical robot serves as an input device to the system. A master arm typically has 6 Degrees of Freedom (DoF) input apart from grasping input used to control the grasping motion of the surgical tool located at the slave arm. The typical design of a master arm grasper makes use of either a gear driven or a crank-slider linkage to capture the grasping input from the surgeon. Such a mechanism has several moving components and needs joints with minimal clearance for reliable operation. A compliant mechanism that features a joint-less design offers superior performance and would serve as an ideal replacement for such a mechanism. This paper presents the design and analysis of a master arm grasper based on a partially compliant mechanism. An inherent advantage of the proposed mechanism for this application is the reduced number of components. Design details and the pseudo-rigid body analysis of the grasper are presented. A prototype of the grasper has been fabricated, and experimental verifications were carried out. The grasper was integrated into a custom-built master arm manipulator to demonstrate its utility in a surgical robot. Results show that the compliant grasper performs well for its intended purpose.
Subjects
  • Compliant mechanisms

  • Flexures

  • Master arm grasper

  • Pseudo rigid body mod...

  • Robotic surgery