Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
Repository logo
  • Communities & Collections
  • Research Outputs
  • Fundings & Projects
  • People
  • Statistics
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Indian Institute of Technology Madras
  3. Publication6
  4. Experimental investigation of thermal performance of metal foam wicked flat heat pipe
 
  • Details
Options

Experimental investigation of thermal performance of metal foam wicked flat heat pipe

Date Issued
01-01-2017
Author(s)
Somasundaram, Dhanabal
Mani, Annamalai
Kamaraj M 
Indian Institute of Technology, Madras
DOI
10.1016/j.expthermflusci.2016.12.006
Abstract
Experimental investigations of thermal performance of a flat heat pipe (FHP) with and without wick columns were investigated. Copper metal foam fabricated by lost carbonate sintering process and characterized by Scanning Electron Microscope (SEM) was used as wick structure. The effect of heat input, cooling water flow rate, cooling water temperature and fill ratio on the thermal response of the FHP is presented. Results showed that the heat transfer coefficient increases with increased Reynolds number and cooling water temperature but decreases with increased heat input and amount of fill ratio. It was found that increasing the wick volume by inserting additional wick columns improves the FHP performance, due to the decreased thermal resistance with increased fluid movement in these additional wick columns. The experimental results were compared with that of analytical calculations at steady state and a good agreement was observed between them.
Volume
82
Subjects
  • Condenser

  • Copper foam

  • Evaporator

  • Flat heat pipe

  • Wick columns (WC)

Indian Institute of Technology Madras Knowledge Repository developed and maintained by the Library