Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
Repository logo
  • Communities & Collections
  • Research Outputs
  • Fundings & Projects
  • People
  • Statistics
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Indian Institute of Technology Madras
  3. Publication3
  4. Influence of bone quality and pedicle screw design on the fixation strength during Axial Pull-out test: A 2D Axisymmetric FE study
 
  • Details
Options

Influence of bone quality and pedicle screw design on the fixation strength during Axial Pull-out test: A 2D Axisymmetric FE study

Date Issued
01-01-2021
Author(s)
Makaram, Harikrishna
Swaminathan, Ramakrishnan 
Indian Institute of Technology, Madras
DOI
10.1109/EMBC46164.2021.9629484
Abstract
Pedicle screw fixations are widely used to provide support and improve stability for the treatment of spinal pathologies. The effectiveness of treatment depends on the anchorage strength between the screw and bone. In this study, the influence of pedicle screw half-angle and bone quality on the displacement of fixation and stress transfer are analyzed using a 2D axisymmetric finite element model. The pedicle screw proximal half-angle is varied between 0° and 60° in steps of 10°, along with two different distal half-angles of 30° and 40°. Three bone models are considered for cancellous bone to simulate various degrees of bone quality, namely, poor, moderate and good. The mechanical properties of cortical bone are kept constant throughout the study. The material properties and boundary conditions are applied based on previous studies. Frictional contact is considered between the bone and screw. Results show that, the displacement of fixation is observed to be minimum at a proximal half angle of 0° and maximum at an angle of 60°, independent of bone quality. The highest implant displacement is observed in case of poor bone quality. All the bone model showed similar patterns of stress distribution, with high stress concentration around the first few threads. The highest peak von Mises stress is obtained at a proximal half-angle of 60°. Furthermore, the stress transfer increased with increase in proximal half-angle and bone quality, with maximum stress transfer at a proximal half-angle of 60°. It appears that, this study might aid to improve the design of pedicle screw for treatment of degenerative spinal diseases.Clinical Relevance - This study analyses the impact of bone quality on pedicle screw design
Indian Institute of Technology Madras Knowledge Repository developed and maintained by the Library

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback