Options
Studies on capillary tube expansion device used in J-T refrigerators operating with nitrogen-hydrocarbon mixtures
Date Issued
01-10-2017
Author(s)
Harish Kruthiventi, S. S.
Indian Institute of Technology, Madras
Abstract
Capillary tube expansion devices are used extensively in small closed cycle J-T refrigerators operating with refrigerant mixtures due to its low cost and the absence of any moving parts. It is possible for J-T refrigerators operating with mixtures that the velocity of refrigerant mixture at capillary tube outlet reaches a value where it equals the speed of sound at certain conditions. The variation of the speed of sound of nitrogen-hydrocarbon mixtures used in J-T refrigerators has been studied in two phase (vapour-liquid) and three-phase (Vapour-liquid-liquid) region as a function of temperature and pressure in this work. Also the conditions under which choking occurs in practical J-T refrigerators is investigated.
Volume
87